Coaxial 2-way switch (DPDT) 2 kW DC-6.5 GHz 24 VDC 7-16 female product photo Front View L
For a larger view click on the picture.

Coaxial 2-way switch (DPDT) 2 kW DC-6.5 GHz 24 VDC 7-16 female

512690C0062
Not available This product is discontinued.

RF characteristics

Number of interfaces:
4
Interface type:
7-16 female (50 Ω) per IEC 61169-4
Interface direction:
straight
Frequency range:
DC to 6.5 GHz
Average power rating:
2.0 kW @ DC to 1 GHz (at -10 to +45 °C ambient temperature)
1.4 kW @ 1 to 2 GHz (at -10 to +45 °C ambient temperature)
1.1 kW @ 2 to 3 GHz (at -10 to +45 °C ambient temperature)
1.0 kW @ 3 to 4 GHz (at -10 to +45 °C ambient temperature)
0.9 kW @ 4 to 5 GHz (at -10 to +45 °C ambient temperature)
0.75 kW @ 5 to 6.5 GHz (at -10 to +45 °C ambient temperature) 1)
Peak voltage:
4.0 kV 1)
VSWR, max.:
1.04 @ DC to 1 GHz
1.08 @ 1 to 3 GHz
1.12 @ 3 to 4 GHz
1.20 @ 4 to 5 GHz
VSWR, typ.:
1.20 @ 5 to 6.5 GHz
Insertion loss max.:
0.05 dB @ DC to 2 GHz
0.10 dB @ 2 to 5 GHz
0.20 dB @ 5 to 6.5 GHz
Isolation, min.:
80 dB @ DC to 3 GHz
60 dB @ 3 to 4 GHz
50 dB @ 4 to 5 GHz
Isolation, typ.:
40 dB @ 5 to 6.5 GHz

Electrical characteristics

Switch type:
built-in
Switch actuator type:
solenoid drive, latching, self cutoff
Operating connector designation:
J1
Operating connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Operating voltage:
21.6 to 28 V DC
Operating current, typ.:
1.1 A 3)
Operating fuses:
2 A (The switch must be externally fused by time-delay)
Control connector designation:
J1
Control connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Control voltage rating remark:
-0.7 mA ( 0 - active ) for U In low
Control fuses:
The circuit must be externally limited to 0.5 A
Interlock connector designation:
J1
Interlock connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Interlock voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Interlock voltage remark:
SELV circuits according to IEC EN 60950-1
Interlock current, max.:
0.5 A
Interlock fuses:
The circuit must be externally limited to 0.5 A
Interlock lead time, typ.:
5 ms (the interlock contacts open 5 ms before and close 2 ms after switching of the RF contacts) 3)
Signaling connector designation:
J1
Signaling connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Switch command hold time, min.:
0.1 s
Switching frequency, max.:
30 operations per minute

Mechanical characteristics

Lifetime:
500,000 operations
Degree of protection:
IP 40
Degree of protection remark:
connected with appropriate gasket
Protection class:
III according to IEC EN 61140
Weight, approx.:
1.2 kg

Environmental conditions

Operational conditions:
ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N
Operating temperature:
-10 to +60 °C 4)
Relative humidity, max.:
95% (condensation not allowed)
Operating altitude, max.:
4000 m (according to IEC EN 60664-1)
Transport conditions:
ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2
Transport temperature range:
-25 to +70 °C
Transport rain, condensation, icing:
not allowed
Storage conditions:
ETSI EN 300 019-1-1 V2.1.4 (2003-04) class 1.2
Storage ambient temperature:
-10 to +60 °C
Storage rain, condensation, icing:
not allowed

Further remarks

1):
Standard conditions:
• Dielectric: Dry air under standard pressure at sea level (p = 1013 hPa)
• Load VSWR, max. 1.0 (no standing wave)
• No modulation, sinusoidal carrier only
2):
Suitable mating connector included
3):
At room temperature and nominal voltage 24 V DC
4):
Extended temperature range on request
Customs tariff number:
85365080

Downloads

512690C0062-DS.pdf

Product data sheet – 512690C0062 – 512690C0062-DS.pdf

M36311.pdf

Product manual – 512690C0062 – M36311.pdf