Coaxial 2-way switch (DPDT) 790 W DC-5 GHz 28 VDC N female latching product photo Front View L
For a larger view click on the picture.

Coaxial 2-way switch (DPDT) 790 W DC-5 GHz 28 VDC N female latching

754030
Compare

RF characteristics

Number of interfaces:
4
Interface type:
N female (50 Ω) per IEC 61169-16
Interface direction:
straight
Frequency range:
DC to 5 GHz
Average power rating:
790 W @ 0 to 1 GHz
560 W @ 1 to 2 GHz
450 W @ 2 to 3 GHz
350 W @ 3 to 5 GHz 1)
Peak voltage:
3.0 kV 1)
VSWR, max.:
1.03 @ DC to 1 GHz
1.13 @ 1 to 3 GHz
1.22 @ 3 to 5 GHz
Insertion loss max.:
0.04 dB @ DC to 2 GHz
0.06 dB @ 2 to 5 GHz
Isolation, min.:
75 dB @ DC to 1 GHz
60 dB @ 1 to 2 GHz
60 dB @ 2 to 3 GHz
50 dB @ 3 to 5 GHz

Electrical characteristics

Switch type:
built-in
Switch actuator type:
solenoid drive, latching, self cutoff
Operating connector designation:
J1
Operating connection:
9 pole connector according to DIN 41652 / IEC 807-2 2)
Operating voltage:
23 to 28 V DC
Operating current, typ.:
0.6 A 3)
Operating fuses:
1 A (The switch must be externally fused by time-delay)
Control connector designation:
J1
Control connection:
9 pole connector according to DIN 41652 / IEC 807-2 2)
Interlock fuses:
The circuit must be externally limited to 0.5 A
Signaling connector designation:
J1
Signaling connection:
9 pole connector according to DIN 41652 / IEC 807-2 2)
Signaling voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Signaling voltage remark:
SELV circuits according to IEC EN 60950-1
Signaling current, max.:
≥ 0.5 A
Switch command hold time, min.:
0.04 s
Switching frequency, max.:
10 operations per minute

Mechanical characteristics

Lifetime:
250,000 operations
Degree of protection:
IP 40
Degree of protection remark:
connected with appropriate gasket
Protection class:
III according to IEC EN 61140
Weight, approx.:
600.0 g

Environmental conditions

Operational conditions:
ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N
Operating temperature:
-10 to +60 °C 4)
Relative humidity, max.:
95% (condensation not allowed)
Transport conditions:
ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2
Transport temperature range:
-25 to +70 °C
Transport rain, condensation, icing:
not allowed
Storage conditions:
ETSI EN 300 019-1-1 V2.1.4 (2003-04) class 1.2
Storage ambient temperature:
-10 to +60 °C 4)
Storage rain, condensation, icing:
not allowed

Further remarks

1):
Standard conditions:
• Dielectric: Dry air under standard pressure at sea level (p = 1013 hPa)
• Load VSWR, max. 1.0 (no standing wave)
• No modulation, sinusoidal carrier only
2):
Suitable mating connector included
3):
At room temperature and nominal voltage 28 V DC
4):
Extended temperature range on request
Customs tariff number:
85365080

Downloads

754030-DS.pdf

Product data sheet – 754030 – 754030-DS.pdf