Coaxial 2-way switch (DPDT) 1000 kW DC-800 MHz 110 VAC 6 1/8" EIA

941989C0110
Compare

RF characteristics

Number of interfaces:
4
Interface type:
6 1/8" EIA (50 Ω) per IEC 60339-2
Interface direction:
straight
Version:
threaded flanges
Frequency range:
DC to 800 MHz
Frequency band:
Band 4/5, Band 3, Band 1, Band 2
Average power rating:
1000 kW @ 1 MHz (at -10 to +45 °C ambient temperature)
350 kW @ 10 MHz (at -10 to +45 °C ambient temperature)
110 kW @ 100 to 230 MHz (at -10 to +45 °C ambient temperature)
60 kW @ 230 to 800 MHz (at -10 to +45 °C ambient temperature) 1)
Peak voltage:
18.6 kV 1)
VSWR, max.:
1.06 @ 1 to 230 MHz
1.08 @ 230 to 800 MHz
Insertion loss max.:
0.03 dB
Isolation, min.:
75 dB @ 1 to 230 MHz
70 dB @ 230 to 800 MHz

Electrical characteristics

Switch type:
built-in
Switch actuator type:
motor drive, latching, self cutoff
Mains connector designation:
J2
Mains connection:
5 pole SPINNER connector BN 126920, certified according to VDE-Reg. No. B687, DIN EN 61984: 2009-11; EN 61984: 2009 2)
Mains connection system:
L, N, PE, TN-System
Operating voltage:
95 to 140 V AC
Operating AC frequency:
50/60 Hz
Operating current, typ.:
1.5 A 3)
Operating fuses:
F1 / F2: 2 A T
Control connector designation:
J1
Control connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Control voltage rating remark:
SELV circuits according to IEC EN 60950-1
Control current, typ.:
12 mA at control voltage 24 V DC
Control fuses:
The circuit must be externally fused to 0.5 A
Interlock connector designation:
J1
Interlock connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Interlock voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Interlock voltage remark:
SELV circuits according to IEC EN 60950-1
Interlock current, max.:
0.5 A
Interlock fuses:
The circuit must be externally limited to 0.5 A
Interlock lead time, typ.:
200 ms (the interlock/signal contacts open 200 ms before and close 200 ms after switching of the RF contacts) 3)
Signaling connector designation:
J1
Signaling connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Signaling voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Signaling voltage remark:
SELV circuits according to IEC EN 60950-1
Signaling current, max.:
≥ 0.5 A
Signaling fuses:
The circuit must be externally limited to 0.5 A
Signaling lead time, typ.:
200 ms (the interlock/signal contacts open 200 ms before and close 200 ms after switching of the RF contacts) 3)
Switch command hold time, min.:
1.2 s
Switching frequency, max.:
3 cycles per minute, max. 30 cycles per hour (6 operations per minute, max. 60 operations per hour)

Mechanical characteristics

Lifetime:
250,000 cycles
500,000 operations
Degree of protection:
IP 40
Degree of protection remark:
connected with appropriate gasket
Protection class:
I according to IEC EN 61140
Weight, approx.:
38.0 kg

Environmental conditions

Operational conditions:
ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N
Operating temperature:
-10 to +60 °C 4)
Relative humidity, max.:
95% (condensation not allowed)
Operating altitude, max.:
4000 m (according to IEC EN 60664-1)
Transport conditions:
ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2
Transport temperature range:
-25 to +70 °C
Transport rain, condensation, icing:
not allowed
Storage conditions:
ETSI EN 300 019-1-1 V2.1.4 (2003-04) class 1.2
Storage ambient temperature:
-10 to +60 °C
Storage rain, condensation, icing:
not allowed

Further remarks

1):
Standard conditions:
• Dielectric: Dry air under standard pressure at sea level (p = 1013 hPa)
• Load VSWR, max. 1.0 (no standing wave)
• No modulation, sinusoidal carrier only
2):
Suitable mating connector included
3):
At room temperature and nominal voltage 120 V AC, 50 Hz
4):
Extended temperature range on request
Customs tariff number:
85353010

Downloads

941989C0110-DS.pdf

Product data sheet – 941989C0110 – 941989C0110-DS.pdf

M36025.pdf

Product manual – 941989C0110 – M36025.pdf