Coaxial bandstop filter GSM-R 200 W 17-16 female

610007

RF characteristics

Number of interfaces:
2
Interface type:
7-16 female (50 Ω) per IEC 61169-4
Interface direction:
straight
Version:
single
Number of cavities:
13
Frequency band:
GSM900
Frequency range passband:
791.0 to 821.0 MHz
832.0 to 862.0 MHz
880.9 to 915.0 MHz
925.9 to 960.0 MHz
1710 to 1880 MHz
1920 to 2170 MHz
2500 to 2690 MHz
Frequency range stopband:
873.1 to 880.1 MHz
918.1 to 925.1 MHz
Average power rating:
200 W
Test voltage rating:
500 V
Return loss min.:
Port 1: 14 dB @ 791 to 821 MHz
Port 1: 14 dB @ 832 to 862 MHz
Port 1: 7 dB @ 880.9 to 882 MHz
Port 1: 7 dB @ 914 to 915 MHz
Port 1: 14 dB @ 882 to 914 MHz
Port 1: 14 dB @ 925.9 to 960 MHz
Port 1: 18 dB @ 1710 to 1880 MHz
Port 1: 18 dB @ 1920 to 2170 MHz
Port 1: 18 dB @ 2500 to 2690 MHz
Insertion loss max.:
1.0 dB @ 791.0 to 821.0 MHz (Passband)
1.0 dB @ 832.0 to 862.0 MHz (Passband)
8.0 dB @ 880.9 to 883.5 MHz (Passband)
1.0 dB @ 883.5 to 914.0 MHz (Passband)
1.8 dB @ 914.0 to 915.0 MHz (Passband)
8.0 dB @ 925.9 to 928.5 MHz (Passband)
1.0 dB @ 928.5 to 960.0 MHz (Passband)
1.0 dB @ 1710 to 1880 MHz (Passband)
1.0 dB @ 1920 to 2170 MHz (Passband)
1.0 dB @ 2500 to 2690 MHz (Passband)
44.0 dB @ 873.1 to 880.1 MHz (Stopband)
44.0 dB @ 918.1 to 925.1 MHz (Stopband)
Passive intermodulation (IM3), max.:
-150 dBc
Passive intermod. (IM3), typ.:
-160 dBc
DC-Bypass:
not defined

Mechanical characteristics

Colour:
grey
IP protection level:
IP 65
Weight, approx.:
15.0 kg

Environmental conditions

Environmental conditions:
ETSI EN 300019-1-1 Class 1.2
ETSI EN 300019-1-2 Class 2.3
ETSI EN 300019-1-4 Class 4.1E
Operating temperature:
-25 to +85 °C

Scope of delivery & accessories

Mounting accessoires:
to be ordered separately under BN B07787

Downloads

610007-DS.pdf

Product data sheet – 610007 – 610007-DS.pdf