OSLT Kit de calibración 1.0 mm clavija 1.0 mm enchufe DC-116.5 GHz Imagen del producto Front View L
Para una vista más grande, haga clic en la imagen.

OSLT Kit de calibración 1.0 mm clavija 1.0 mm enchufe DC-116.5 GHz

535742
Comparar

Características de radiofrecuencia

Número de interfaces:
12
Tipo de interfaz:
1.0 mm clavija (50 Ω) conforme a IEC 61169-31
1.0 mm enchufe (50 Ω) conforme a IEC 61169-31
Dirección de interfaz:
derecha
Gama de frecuencias:
DC a 116.5 GHz
(sin resonancia hasta 120 GHz)
Potencia, máx. LOAD:
50,0 mW
Factor de adaptación, mín. THROUGH:
27 dB @ DC a 10 GHz
24 dB @ 10 a 26.5 GHz
21 dB @ 26.5 a 50 GHz
18 dB @ 50 a 70 GHz
15 dB @ 70 a 90 GHz
12 dB @ 90 a 116.5 GHz
Factor de adaptación, mín. LOAD:
31 dB @ DC a 10 GHz
25 dB @ 10 a 26.5 GHz
22 dB @ 26.5 a 70 GHz
17 dB @ 70 a 116.5 GHz
Pérdida de inserción, máx. THROUGH:
0.7 dB
Estabilidad de pérdida de inserción, típica:
0.5 dB
Resistencia DC LOAD:
50 Ω (±0.5 Ω)

Características mecánicas

Material / revestimiento de conductor interior:
CuBe curado / dorado
Material / revestimiento de conductor de línea :
aleación de cobre / dorado
Material de aislamiento:
PS
Peso, aprox.:
1,4 kg
Marcado:
laser engraving

Condiciones ambientales

Temperatura de funcionamiento:
+18 a +28 °C 1)
Humedad relativa, máx.:
95% (non-condensing)
Gama de temperatura de almacenaje:
-40 a +70 °C (de acuerdo a EN 60068-2-1 e EN 60068-2-2)
Humedad relativa para el almacenamiento, máx.:
95% (non-condensing)

Alcance de entrega y accesorios

Volumen de entrega:
1 x 1.0 mm open circuit plug (BN 535733, factory calibration option)
1 x 1.0 mm open circuit socket (BN 535734, factory calibration option)
1 x 1.0 mm short circuit plug (BN 535735, factory calibration option)
1 x 1.0 mm short circuit socket (BN 535736, factory calibration option)
1 x 1.0 mm load plug (BN 535737, factory calibration option)
1 x 1.0 mm load socket (BN 535738, factory calibration option)
1 x 1.0 mm through plug / plug (BN 535739, factory calibration option)
1 x 1.0 mm through socket / socket (BN 535740, factory calibration option)
1 x 1.0 mm through plug / socket (BN 535741, factory calibration option)
1 x torque wrench 6 mm / 45 N cm (BN 238748C0001, factory calibration option)
1 x torque wrench 6 mm / 34 N cm (BN 238749C0001, factory calibration option)
1 x double open-ended spanner 7 mm (BN 238750)

calibration certificate, USB-flash drive with calibration data and documentation, handling instruction torque wrench, aluminum storage case

Más observaciones

Anotación:
Calibration data:
Calibration data includes determined S-parameters for OPEN, SHORT and LOAD standards to achieve best possible performance.

Re-Calibration
The suggested initial interval for recalibration is 12 months or 500 matings, whichever comes first. The actual need for recalibration depends on the use and the maintenance of the kit. The recalibration interval should begin with the day of initial use after recalibration.

Pin Depth Limits:
Pin depth is the distance between outer conductor mating plane and inner conductor mating plane. Negative values stand for protrusion of the inner conductor, positive values for recession.
Partida arancelaria:
90309000

Anexos

535742-DS.pdf

Ficha técnica de producto – 535742 – 535742-DS.pdf

REACH_Test&Measurement_10123444-TD.pdf

Technical document – 535742 – REACH-Certificate para Test & Measurement Products – REACH_Test&Measurement_10123444-TD.pdf

RoHS_Test&Measurement_10121583-TD.pdf

Technical document – 535742 – RoHS-Certificate para Test & Measurement Products – RoHS_Test&Measurement_10121583-TD.pdf

10093398.pdf

Manual del producto – 535742 – 10093398.pdf

10093494.pdf

Instrucciones de manejo – 535742 – 10093494.pdf