OSLT Kit de calibración N clavija N enchufe Imagen del producto Front View L
Para una vista más grande, haga clic en la imagen.

OSLT Kit de calibración N clavija N enchufe

533861
Comparar

Características de radiofrecuencia

Número de interfaces:
10
Tipo de interfaz:
N clavija (75 Ω) conforme a IEC 61169-16
N enchufo (75 Ω) conforme a IEC 61169-16
Dirección de interfaz:
derecha
Gama de frecuencias:
DC a 18 GHz
Potencia, máx. LOAD:
500,0 mW
Factor de adaptación, mín. THROUGH:
38 dB @ DC a 4 GHz
34 dB @ 4 a 8 GHz
32 dB @ 8 a 12 GHz
28 dB @ 12 a 18 GHz
Factor de adaptación, mín. LOAD:
42 dB @ DC a 6 GHz
38 dB @ 6 a 8 GHz
35 dB @ 8 a 12 GHz
33 dB @ 12 a 18 GHz
Pérdida de inserción, máx. THROUGH:
0.04 dB x √("f (GHz)" )
Desviación de fase, máx. OPEN:
1.0 ° @ DC a 4 GHz
1.25 ° @ 4 a 8 GHz
1.5 ° @ 8 a 12 GHz
2.0 ° @ 12 a 18 GHz 1)
Desviación de fase, máx. SHORT:
1.0 ° @ DC a 4 GHz
1.25 ° @ 4 a 8 GHz
1.5 ° @ 8 a 12 GHz
2.0 ° @ 12 a 18 GHz 1)
Resistencia DC LOAD:
50 Ω (±0.5 Ω)

Características mecánicas

Norma:
IEC 61169-16
Material / superficie de conductor interior:
CuBe curado / dorado
Material / superficie de conductor de línea :
aleación de cobre / dorado
Material / superficie de otras partes metálicas:
aleación de cobre / niquelado
Aislamiento:
PMP
Peso, aprox.:
1,8 kg
Marcado:
grabado láser

Condiciones ambientales

Temperatura de funcionamiento:
+18 a +28 °C 2)
Humedad relativa, máx.:
95% (a 40 °C, condensación prohibida)
Gama de temperatura de almacenaje:
-40 a +70 °C (de acuerdo a EN 60068-2-1 e EN 60068-2-2)

Volumen de entrega y accesorios

Volumen de entrega:
calibration certificate, USB-Stick with calibration data and documentation, open end torque wrench AF 19 with torque setting 90 N∙cm, aluminum storage case

Más observaciones

1):
The specifications for the opens and shorts are given as allowed deviation from the nominal model as defined in the calibration data.
2):
Temperature range within all components maintain conformance to their specification.
3):
Ranges of measurement is the limit that could be measured with a suitable gauge due to the measurement uncertainty. These values could still be within the specification. The measurement uncertainty is based on the measurement with SPINNER gauges, mounting torque 90 N∙cm and the specified operating temperature. Deviation from these conditions may cause higher measurement uncertainty.
Anotación:
Calibration data:
Calibration data in formats for the common VNAs are included in the kit. It includes offset length and individual calibration coefficients for every kit to achieve the best possible performance.

Pin Depth Limits:
Pin depth is the distance between outer conductor mating plane and inner conductor mating plane. Positive values stand for protrusion of the inner conductor, negative values for recession.

Anexos

533861-DS.pdf

Ficha técnica de producto – 533861 – 533861-DS.pdf

M36081.pdf

Instrucciones de manejo – 533861 – M36081.pdf