Product manual – 512690C0002 – M36311.pdf

Number of interfaces
Number of interfaces
4
Interface type
Interface type
7-16 female (50 Ω) per IEC 61169-4
Interface direction
Interface direction
straight
Frequency range
Frequency range
DC to 5 GHz
Average power rating
Average power rating
2.0 kW @ DC to 1 GHz (at -10 to +45 °C ambient temperature)
1.4 kW @ 1 to 2 GHZ (at -10 to +45 °C ambient temperature)
1.1 kW @ 2 to 3 GHz (at -10 to +45 °C ambient temperature)
1.0 kW @ 3 to 4 GHz (at -10 to +45 °C ambient temperature)
0.9 kW @ 4 to 5 GHz (at -10 to +45 °C ambient temperature) 1)
Peak voltage
Peak voltage
4.0 kV 1)
VSWR, max.
VSWR, max.
1.04 @ DC to 1 GHz
1.08 @ 1 to 3 GHz
1.12 @ 3 to 4 GHz
1.20 @ 4 to 5 GHz
Insertion loss max.
Insertion loss max.
0.05 dB @ DC to 1 GHz
0.05 dB @ 1 to 2 GHz
0.10 dB @ 2 to 3 GHz
0.10 dB @ 3 to 4 GHz
0.10 dB @ 4 to 5 GHz
Isolation, min.
Isolation, min.
80 dB @ DC to 1 GHz
80 dB @ 1 to 2 GHz
80 dB @ 2 to 3 GHz
60 dB @ 3 to 4 GHz
50 dB @ 4 to 5 GHz
Switch type
Switch type
built-in
Switch actuator type
Switch actuator type
solenoid drive, latching, self cutoff
Operating connector designation
Operating connector designation
J1
Operating connection
Operating connection
25 pole connector according to DIN 41652 / IEC 807-2 2)
Operating voltage
Operating voltage
21.6 to 28 V DC
Operating current, typ.
Operating current, typ.
1.1 A 3)
Operating fuses
Operating fuses
2 A (The switch must be externally fused by time-delay)
Control connector designation
Control connector designation
J1
Control connection
Control connection
25 pole connector according to DIN 41652 / IEC 807-2 2)
Control voltage rating remark
Control voltage rating remark
-0.7 mA ( 0 - active ) for U In low
Control fuses
Control fuses
The circuit must be externally limited to 0.5 A
Interlock connector designation
Interlock connector designation
J1
Interlock connection
Interlock connection
25 pole connector according to DIN 41652 / IEC 807-2 2)
Interlock voltage
Interlock voltage
≥ 42.4 V ACpk
≥ 60 V DC
Interlock voltage remark
Interlock voltage remark
SELV circuits according to IEC EN 60950-1
Interlock current, max.
Interlock current, max.
0.5 A
Interlock fuses
Interlock fuses
The circuit must be externally limited to 0.5 A
Interlock lead time, typ.
Interlock lead time, typ.
5 ms (the interlock contacts open 5 ms before and close 2 ms after switching of the RF contacts) 3)
Signaling connector designation
Signaling connector designation
J1
Signaling connection
Signaling connection
25 pole connector according to DIN 41652 / IEC 807-2 2)
Switch command hold time, min. (in s)
Switch command hold time, min. (in s)
0.1 s
Switching frequency, max.
Switching frequency, max.
30 operations per minute
Lifetime
Lifetime
500,000 operations
IP protection level
IP protection level
IP 40
IP protection level remark
IP protection level remark
connected with appropriate gasket
Protection class
Protection class
III according to IEC EN 61140
Weight, approx. (in kg)
Weight, approx. (in kg)
1.2 kg
Operational conditions
Operational conditions
ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N
Operating temperature
Operating temperature
-10 to +60 °C 4)
Relative humidity, max.
Relative humidity, max.
95% (condensation not allowed)
Operating altitude, max.
Operating altitude, max.
4000 m according to IEC EN 60664-1
Transport conditions
Transport conditions
ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2
Transport temperature range
Transport temperature range
-25 to +70 °C
Transport rain, condensation, icing
Transport rain, condensation, icing
not allowed
Storage conditions
Storage conditions
ETSI EN 300 019-1-1 V2.1.4 (2003-04) class 1.2
Storage ambient temperature
Storage ambient temperature
-10 to +60 °C
Storage rain, condensation, icing
Storage rain, condensation, icing
not allowed
Remark
Remark
Fully compatible to BN 512690
1)
1)
Standard conditions:
• Dielectric: Dry air under standard pressure at sea level (p = 1013 hPa)
• Load VSWR, max. 1.0 (no standing wave)
• No modulation, sinusoidal carrier only
2)
2)
Suitable mating connector included
3)
3)
At room temperature and nominal voltage 24 V DC
4)
4)
Extended temperature range on request