OSLT calibration kit 1.35 mm male 1.35 mm female

534936
Compare

Precision Calibration Kits - all necessary calibration standards in one sturdy case

Nowadays, no development, production, testing, or quality control department that deals with RF signals on coaxial lines can afford to dispense with state-of-the-art high-precision equipment. It’s essential to use vector network analyzers (VNAs) in particular with high-precision connectors, terminations, and adapters.

Systematic errors can be fixed by calibrating the VNA. Different calibration standards with defined and known electrical characteristics are applied and compared to identify error coefficients. A technique called vector error correction is used to characterize error terms while applying known standards in order to remove errors from actual measurements and increase the accuracy of the results. A VNA can be calibrated in different ways depending on the required degree of accuracy. The methods used differ in both the number and the type of the calibration standards applied. The most commonly used calibration approaches are OSL (which stands for open-short-load) for single-port measurements and OSLT (for open-short-load-through) for multiple-port measurements. The order of the standards can vary in the designation; for example, the abbreviation SOLT is occasionally used synonymously. OSLT precision calibration kits are used worldwide for High-end S-parameter measurements for the development of RF components for mobile communication, broadcast, radar applications, satellite communication, automotive engineering and manufacturing, mechanical engineering and many other industrial applications. The OSLT calibration kit 1.35 mm male 1.35 mm female offers the combination of all necessary calibration standards in one robust aluminum case. It is the optimal and high quality solution for a convenient and complete calibration of a network analyser with two or more ports using the OSLT procedure with the calibration standards open circuits (O, open), short circuits (S, short), fixed loads (L, load) and through adapters (T, through). Each one is provided in male and female version including through adapters, one with male-to-male and one with female-to-female connections. Optionally a male-to-female is available. Calibration data in digital formats for common VNAs are included on a USB-stick in the kit. It includes individual calibration coefficients determined during manufacture for every kit to achieve the best possible accuracy.

The OSLT calibration kit 1.35 mm male 1.35 mm female has a characteristic impedance of 50 Ω. It is characterised by very low VSWR and attenuation values as well as best intermodulation properties in the entire operating frequency range from DC to 90 GHz.

This product has gold-plated connections and is based on the better quality classes of the IEEE, ICE standards with regard to lower tolerances. SPINNER also uses the term ‘precision’ here to emphasize the suitability for exceptionally high-precision measurements.

The SPINNER 1.35 mm connector is the best high-precision coaxial connector for E-band applications, a robust precision interface for DC up to 90 GHz. Especially in E-band applications, reliable coaxial interface connections are crucial for achieving good RF performance.

The suggested initial interval for recalibration is 12 months or 500 mating’s, whichever comes first. The actual need for recalibration depends on the use and the maintenance of the kit. The recalibration interval should begin with the day of initial use after recalibration.

SPINNER RF measurement components meet highest standards

SPINNER has set new standards of accuracy with this product line, which includes a large family of coaxial test equipment with outstanding electrical and mechanical attributes for use in laboratory and production environments. For the production SPINNER applies extremely high standards regarding quality, engineering, materials and manufacturing e.g. DIN EN ISO 9001 - Quality Management, DIN EN ISO 14001 - Environmental Management and ISO 50001:2011 - Energy Management. This enables us to offer precision calibration kits with the best possible performance and lowest possible intermodulation (Low PIM).

RF characteristics

Number of interfaces:
10
Interface type:
1.35 mm male (50 Ω) per IEEE Std 287
1.35 mm female (50 Ω) per IEEE Std 287
Interface direction:
straight
Frequency range:
DC to 90 GHz
Power rating, max. LOAD:
100.0 mW
Return loss, min. THROUGH:
27 dB @ DC to 10 GHz
24 dB @ 10 to 26.5 GHz
21 dB @ 26.5 to 50 GHz
18 dB @ 50 to 70 GHz
15 dB @ 70 to 90 GHz
Return loss, min. LOAD:
31 dB @ DC to 10 GHz
25 dB @ 10 to 26.5 GHz
20 dB @ 26.5 to 50 GHz
14 dB @ 50 to 70 GHz
10 dB @ 70 to 90 GHz
Insertion loss, max. THROUGH:
0.07 dB x √("f (GHz)" )
DC-resistance LOAD:
50 Ω (±0.5 Ω)

Mechanical characteristics

Inner conductor material / surface coating:
CuBe age hardened / gold-plated
Outer conductor material / coating:
CuBe / gold-plated
Insulation material:
PS
Weight, approx.:
1.1 kg
Marking:
laser engraving

Environmental conditions

Operating temperature:
+18 to +28 °C 1)
Storage ambient temperature:
-40 to +70 °C (according to EN 60068-2-1 and EN 60068-2-2)

Scope of delivery & accessories

Delivery scope:
calibration certificate, USB-Stick with calibration data and documentation (S-parameter-files for OPEN, SHORT, LOAD), aluminum storage case

Further remarks

1):
Temperature range within all components maintain conformance to their specification.
2):
Ranges of measurement is the limit that could be measured with a suitable gauge due to the measurement uncertainty. These values could still be within the specification. The measurement uncertainty is based on the measurement with SPINNER gauges and the specified operating temperature. Deviation from these conditions may cause higher measurement uncertainty.
Footnote:
Calibration data:
Calibration data includes determined S-parameters for OPEN, SHORT and LOAD standards to achieve best possible performance.

Re-Calibration
The suggested initial interval for recalibration is 12 months or 500 matings, whichever comes first. The actual need for recalibration depends on the use and the maintenance of the kit. The recalibration interval should begin with the day of initial use after recalibration.

Pin Depth Limits:
Pin depth is the distance between outer conductor mating plane and inner conductor mating plane. Positive values stand for protrusion of the inner conductor, negative values for recession.
Customs tariff number:
90309000

Downloads

534936-DS.pdf

Product data sheet – 534936 – 534936-DS.pdf

REACH_Test&Measurement_10123444-TD.pdf

Technical document – 534936 – REACH-Certificate for Test & Measurement Products – REACH_Test&Measurement_10123444-TD.pdf

RoHS_Test&Measurement_10121583-TD.pdf

Technical document – 534936 – RoHS-Certificate for Test & Measurement Products – RoHS_Test&Measurement_10121583-TD.pdf

M31071.pdf

Handling instructions – 534936 – M31071.pdf

M36081.pdf

Handling instructions – 534936 – M36081.pdf

M36515.pdf

Product manual – 534936 – M36515.pdf