OSLT calibration kit 1.85 mm male 1.85 mm female product photo Front View L
For a larger view click on the picture.

OSLT calibration kit 1.85 mm male 1.85 mm female

533855
Not available This product is discontinued.

Precision Calibration Kits - all necessary calibration standards in one sturdy case

Nowadays, no development, production, testing, or quality control department that deals with RF signals on coaxial lines can afford to dispense with state-of-the-art high-precision equipment. It’s essential to use vector network analyzers (VNAs) in particular with high-precision connectors, terminations, and adapters.

Systematic errors can be fixed by calibrating the VNA. Different calibration standards with defined and known electrical characteristics are applied and compared to identify error coefficients. A technique called vector error correction is used to characterize error terms while applying known standards in order to remove errors from actual measurements and increase the accuracy of the results. A VNA can be calibrated in different ways depending on the required degree of accuracy. The methods used differ in both the number and the type of the calibration standards applied. The most commonly used calibration approaches are OSL (which stands for open-short-load) for single-port measurements and OSLT (for open-short-load-through) for multiple-port measurements. The order of the standards can vary in the designation; for example, the abbreviation SOLT is occasionally used synonymously. OSLT precision calibration kits are used worldwide for High-end S-parameter measurements for the development of RF components for mobile communication, broadcast, radar applications, satellite communication, automotive engineering and manufacturing, mechanical engineering and many other industrial applications. The OSLT calibration kit 1.85 mm male 1.85 mm female offers the combination of all necessary calibration standards in one robust aluminum case. It is the optimal and high quality solution for a convenient and complete calibration of a network analyser with two or more ports using the OSLT procedure with the calibration standards open circuits (O, open), short circuits (S, short), fixed loads (L, load) and through adapters (T, through). Each one is provided in male and female version including through adapters, one with male-to-male and one with female-to-female connections. Optionally a male-to-female is available. Calibration data in digital formats for common VNAs are included on a USB-stick in the kit. It includes individual calibration coefficients determined during manufacture for every kit to achieve the best possible accuracy.

The OSLT calibration kit 1.85 mm male 1.85 mm female has a characteristic impedance of 50 Ω. It is characterised by very low VSWR and attenuation values as well as best intermodulation properties in the entire operating frequency range from DC to 67 GHz.

This product has gold-plated connections and is based on the better quality classes of the IEEE, ICE standards with regard to lower tolerances. SPINNER also uses the term ‘precision’ here to emphasize the suitability for exceptionally high-precision measurements.

The 1.85mm connector was first proposed and introduced in 1986 and soon used on Vector Network Analysers. The 1.85 mm coaxial connector has an air-filled dielectric interface. 1.85 mm precision connectors are particularly suitable for use in radio-frequency test and measurement laboratories for frequencies up to approx. 70 GHz. They are designed with excellent characteristics and tight tolerances over the entire specified frequency range. They are an advancement of the coaxial 2.92-mm connector size and are known as Type-V connectors.

The suggested initial interval for recalibration is 12 months or 500 mating’s, whichever comes first. The actual need for recalibration depends on the use and the maintenance of the kit. The recalibration interval should begin with the day of initial use after recalibration.

SPINNER RF measurement components meet highest standards

SPINNER has set new standards of accuracy with this product line, which includes a large family of coaxial test equipment with outstanding electrical and mechanical attributes for use in laboratory and production environments. For the production SPINNER applies extremely high standards regarding quality, engineering, materials and manufacturing e.g. DIN EN ISO 9001 - Quality Management, DIN EN ISO 14001 - Environmental Management and ISO 50001:2011 - Energy Management. This enables us to offer precision calibration kits with the best possible performance and lowest possible intermodulation (Low PIM).

RF characteristics

Number of interfaces:
10
Interface type:
1.85 mm male (50 Ω) per IEC 61169-32
1.85 mm female (50 Ω) per IEC 61169-32
Interface direction:
straight
Frequency range:
DC to 67 GHz
Return loss, min. THROUGH:
32 dB @DC to 4 GHz
30 dB @ 4 to 26.5 GHz
25 dB @ 26.5 to 40 GHz
23 dB @ 40 to 67 GHz 2)
Return loss, min. LOAD:
36 dB DC to 4 GHz
31 dB 4 to 10 GHz
25 dB 10 to 26.5 GHz
22 dB 26.5 to 50 GHz
20 dB 50 to 67 GHz
Phase deviation, max. OPEN:
2 ° @ DC to 26.5 GHz
3.5 ° @ 26.5 to 50 GHz
4.5 ° @ 50 to 67 GHz 1)
Phase deviation, max. SHORT:
2 ° @ DC to 26.5 GHz
3 ° @ 26.5 to 50 GHz
4 ° @ 50 to 67 GHz 1)
DC-resistance LOAD:
50 Ω (±0.5 Ω) 2)

Mechanical characteristics

Standards:
IEC 61169-32
Inner conductor material / surface coating:
CuBe age hardened / gold-plated
Outer conductor material / coating:
CuBe / gold-plated
Insulation material:
PMP, PEEK
Weight, approx.:
1.3 kg

Environmental conditions

Operating temperature:
+18 to +28 °C 3)
Relative humidity, max.:
95% (at 40 °C, condensation not allowed)
Storage ambient temperature:
-40 to +70 °C

Scope of delivery & accessories

Delivery scope:
calibration certificate, USB-Stick with calibration data and documentation, open end torque wrench AF 8 with torque setting 90 N∙cm, aluminum storage case

Further remarks

1):
The specifications for the opens and shorts are given as allowed deviation from the nominal model as defined in the calibration data.
2):
Electrical values for adapter (THROUGHs) plug-plug, socket-socket and plug-socket
3):
Temperature range within all components maintain conformance to their specification.
4):
Ranges of measurement is the limit that could be measured with a suitable gauge due to the measurement uncertainty. These values could still be within the specification. The measurement uncertainty is based on the measurement with SPINNER gauges, mounting torque 90 N∙cm and the specified operating temperature. Deviation from these conditions may cause higher measurement uncertainty.
Footnote:
Calibration data:
Calibration data in formats for the common VNAs are included in the kit. It includes individual calibration coefficients for every kit to achieve the best possible performance.

Pin Depth Limits:
Pin depth is the distance between outer conductor mating plane and inner conductor mating plane. Positive values stand for protrusion of the inner conductor, negative values for recession.
Customs tariff number:
90309000

Downloads

533855-DS.pdf

Product data sheet – 533855 – 533855-DS.pdf

M36040.pdf

Product manual – 533855 – M36040.pdf

M36081.pdf

Handling instructions – 533855 – M36081.pdf