Loads

Interface size

    Interface gender

      Power rating max.

        Frequency min.

          Frequency max.

          Cooling type

            625 W load DC-860 MHz  7-16 female product photo
            625 W load DC-860 MHz 7-16 female
            BN:
            537701
            VSWR, max.:
            1.06 @ DC to 860 MHz
            Weight, approx.:
            1.0 kg
            Compare
            50 W load DC-860 MHz  N male product photo
            50 W load DC-860 MHz N male
            BN:
            537713
            VSWR, max.:
            1.06
            Weight, approx.:
            1.0 kg
            Compare
            200 W load DC-860 MHz  7-16 female product photo
            200 W load DC-860 MHz 7-16 female
            BN:
            537730
            VSWR, max.:
            1.06 @ DC to 860 MHz
            Weight, approx.:
            2.0 kg
            Compare
            400 W load DC-860 MHz  7-16 female product photo
            400 W load DC-860 MHz 7-16 female
            BN:
            537740
            VSWR, max.:
            1.06 @ DC to 860 MHz
            Degree of protection:
            IP 40
            Weight, approx.:
            5.0 kg
            Compare
            2000 W load DC-860 MHz  1 5/8" EIA product photo
            2000 W load DC-860 MHz 1 5/8" EIA
            BN:
            537770
            VSWR, max.:
            1.06 @ DC to 860 MHz
            Degree of protection:
            IP 40
            Weight, approx.:
            32.0 kg
            Compare
            2.5 kW load DC-860 MHz  1 5/8" EIA product photo
            2.5 kW load DC-860 MHz 1 5/8" EIA
            BN:
            537794
            VSWR, max.:
            1.11 @ DC to 860 MHz
            Degree of protection:
            IP 40
            Weight, approx.:
            32.0 kg
            Compare
            25 kW SmartLoad DC-860 MHz 230 V 3 1/8" EIA product photo
            25 kW SmartLoad DC-860 MHz 230 V 3 1/8" EIA
            BN:
            546404C0300
            VSWR, max.:
            1.04 @ DC to 108 MHz
            1.04 @ 108 to 470 MHz
            1.04 @ 470 to 860 MHz
            1.08 @ DC to 860 MHz
            Mains voltage:
            115 V
            Degree of protection:
            IP 20
            Weight, approx.:
            130.0 kg
            Compare
            25 kW SmartLoad DC-860 MHz 115 V 3 1/8" EIA product photo
            25 kW SmartLoad DC-860 MHz 115 V 3 1/8" EIA
            BN:
            546404C0301
            VSWR, max.:
            1.04 @ DC to 108 MHz
            1.04 @ 108 to 470 MHz
            1.04 @ 470 to 860 MHz
            1.08 @ DC to 860 MHz
            Mains voltage:
            230 V
            Degree of protection:
            IP 20
            Weight, approx.:
            140.0 kg
            Compare
            25 kW SmartLoad DC-860 MHz 230 V 3 1/8" EIA with wheels product photo
            25 kW SmartLoad DC-860 MHz 230 V 3 1/8" EIA with wheels
            BN:
            546404C0400
            VSWR, max.:
            1.04 @ DC to 108 MHz
            1.04 @ 108 to 470 MHz
            1.04 @ 470 to 860 MHz
            1.08 @ DC to 860 MHz
            Mains voltage:
            115 V
            Degree of protection:
            IP 20
            Weight, approx.:
            130.0 kg
            Compare
            25 kW SmartLoad DC-860 MHz 115 V 3 1/8" EIA with wheels product photo
            25 kW SmartLoad DC-860 MHz 115 V 3 1/8" EIA with wheels
            BN:
            546404C0401
            VSWR, max.:
            1.04 @ DC to 108 MHz
            1.04 @ 108 to 470 MHz
            1.04 @ 470 to 860 MHz
            1.08 @ DC to 860 MHz
            Mains voltage:
            230 V
            Degree of protection:
            IP 20
            Weight, approx.:
            140.0 kg
            Compare
            25 kW load DC-860 MHz 3 1/8" EIA with temperature sensor product photo
            25 kW load DC-860 MHz 3 1/8" EIA with temperature sensor
            BN:
            546418
            VSWR, max.:
            1.04 @ DC to 108 MHz
            1.04 @ 108 to 470 MHz
            1.04 @ 470 to 860 MHz
            1.08 @ DC to 860 MHz
            Degree of protection:
            IP 20
            Weight, approx.:
            7.0 kg
            Compare
            10 kW SmartLoad DC-860 MHz 230 V 3 1/8" EIA product photo
            10 kW SmartLoad DC-860 MHz 230 V 3 1/8" EIA
            BN:
            546423C0300
            VSWR, max.:
            1.04 @ DC to 108 MHz or
            1.04 @ 108 to 470 MHz or
            1.04 @ 470 to 860 MHz or
            1.08 @ DC to 860 MHz
            Mains voltage:
            230 V
            Degree of protection:
            IP 20
            Weight, approx.:
            85.0 kg
            Compare

            Loads – for your applications from 0.5 to 50,000 W

            SPINNER carries an extensive portfolio of loads. In addition to products with excellent VSWR values, we also offer low-intermodulation (low PIM) versions for use in mobile networks.

            SPINNER Ioads and attenuators are often used in the installation and calibration of mobile radio communication stations, but also in measurement technology applications in which they excel thanks to their excellent IM properties.

            For both loads and attenuators up to 200 watts, SPINNER has introduced a new modular system that gives you considerably more flexibility for choosing your mobile communication or measurement components. The benefits are obvious: cost savings and improved technical values.

            Loads and attenuators have to meet diverse requirements in terms of performance and connector systems, and the new system makes it simple for you to get exactly what you need. You can freely specify your components and avoid having to use adaptors or products that are larger or more powerful than actually needed for your application.

            The new modular system is available for the 25 W, 50 W, 100 W and 200 W performance versions as well as for 7- 16, 4.3-10 and N connector systems. The standard version is available between 0 and 4 GHz. Extended versions are possible up to 6 GHz. Moreover, you can order your versions with an integrated DC Break as well as with a measurement report.

            Most of our loads for broadcast applications in the power consumption range from 2 kW to 5 kW are produced using the planar process. For values between 10 kW and 50 kW, we use liquid cooling with a fluid mixture that prevents freezing and corrosion. For products above 10 kW, we also offer closed-circuit cooling and safety features such as carrier safety loops and temperature monitoring.

             

            SPINNER RF components meet highest standards

            SPINNER applies extremely high standards regarding quality, engineering, materials and manufacturing e.g. DIN EN ISO 9001 - Quality Management, DIN EN ISO 14001 - Environmental Management and ISO 50001:2011 - Energy Management. This enables us to offer loads with the best possible performance and lowest possible intermodulation.

            If you can’t find a load according to your specifications online, please contact our sales team with the specification needed per email or select one of the displayed loads for a Quote Request and add your special requirements in the comment field of the form before submitting.