Compact Calibration Kits

Interface size

Interface gender

Characteristic impedance

    Frequency min.

      Frequency max.

        8 Items
        • «
        • 1
        • »
        OSL compact calibration kit (3-in-1) DC-18 GHz N female product photo
        OSL compact calibration kit (3-in-1) DC-18 GHz N female
        BN:
        533177
        Frequency range:
        DC to 18 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        250.0 g
        Operating temperature:
        +5 to +40 °C
        Compare
        OSLT compact calibration kit (4-in-1) DC-9 GHz N female product photo
        OSLT compact calibration kit (4-in-1) DC-9 GHz N female
        BN:
        533843
        Frequency range:
        DC to 9 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        250.0 g
        Operating temperature:
        -10 to +55 °C
        Compare
        OSLT compact calibration kit (4-in-1) DC-3 GHz N female (75 Ω) product photo
        OSLT compact calibration kit (4-in-1) DC-3 GHz N female (75 Ω)
        BN:
        533857R000
        Frequency range:
        DC to 3 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        250.0 g
        Operating temperature:
        -10 to +55 °C
        Compare
        OSL compact calibration kit (3-in-1) DC-7.5 GHz N female product photo
        OSL compact calibration kit (3-in-1) DC-7.5 GHz N female
        BN:
        533863R000
        Frequency range:
        DC to 7.5 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        200.0 g
        Operating temperature:
        -10 to +55 °C
        Compare
        OSLT compact calibration kit (4-in-1) DC-18 GHz N female product photo
        OSLT compact calibration kit (4-in-1) DC-18 GHz N female
        BN:
        533880
        Frequency range:
        DC to 18 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        250.0 g
        Operating temperature:
        +18 to +28 °C
        +5 to +40 °C (permissible operating temperature)
        Compare
        OSLT compact calibration kit (4-in-1) DC-12 GHz N female (75 Ω) product photo
        OSLT compact calibration kit (4-in-1) DC-12 GHz N female (75 Ω)
        BN:
        534029
        Frequency range:
        DC to 12 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        250.0 g
        Operating temperature:
        -10 to +55 °C
        Compare
        OSLT compact calibration kit (4-in-1) DC-20 GHz N female (75 Ω) product photo
        OSLT compact calibration kit (4-in-1) DC-20 GHz N female (75 Ω)
        BN:
        534051
        Frequency range:
        DC to 20 GHz
        Power rating, max. LOAD:
        500.0 mW
        Weight, approx.:
        50.0 g
        Operating temperature:
        +18 to +28 °C
        Compare
        Measurement accessory kit for 75 Ω direct access unit product photo
        Measurement accessory kit for 75 Ω direct access unit
        BN:
        876794
        Frequency range:
        DC to 3 GHz (OSLT combination, load, short, cable) 1)
        DC to 18 GHz (adapter)
        Weight, approx.:
        500.0 g
        Operating temperature:
        -10 to +55 °C
        Compare
        8 Items
        • «
        • 1
        • »

        Compact Calibration Kits

        The combination of all calibration standards in one handy unit is the optimum solution for simple and comfortable handling during the calibration of network analyzers with the methods OSL and OSLT. The excellent handling, ergonomic arrangement of the components, small size and low weight are appreciated by in-field users as well.

        SPINNERs 4-in-1 calibration kits include Open, Short, Load and Through lines for completely calibrating a vector network analyzer (VNA) with two or more ports using the OSLT method.

        SPINNERs 3-in-1 calibration kits include all necessary standards for a complete OSL (Open, Short, Load) calibration of single port vector network analyzers, which are mainly used for field testing of wireless network installations.

        Compact calibration Kits are available with 1.85 mm, 2.4 mm, 2.92 mm, 3.5 mm, 2.2-5, NEX10®, 4.1-9.5, 4.3-10, N and 7-16 connector standards, for 50 Ω or 75 Ω systems and for frequency ranges up to 67 GHz.

         

        SPINNER RF components meet highest standards

        SPINNER applies extremely high standards regarding quality, engineering, materials and manufacturing e.g. DIN EN ISO 9001 - Quality Management, DIN EN ISO 14001 - Environmental Management and ISO 50001:2011 - Energy Management. This enables us to offer compact calibration kits with the best possible performance and lowest possible intermodulation (Low PIM), even under the harshest environmental conditions.

        If you can’t find your compact calibration kit according to your specifications online, please contact our sales team with the specification needed per email or select one of the displayed products for a Quote Request and add your special requirements in the comment field of the form before submitting.